Jump Detection Rule Type

The Jump Detection rule type checks whether the current measured value has a value jump compared to the calculated minimum or maximum value of the previous measured values. The event is triggered if the difference between the current measured value and the calculated minimum or maximum value of the previous measured values exceeds the configured jump value.

Calculation of the value, for comparison with the jump value:

Example

A machine presses constantly with approx. 10 kN. In the rule, the value jump is set to 0.5 and the observation period is set to 60 seconds. Over the last 60 seconds, the average value was 9.9 kN.

If the average value of the measurements then falls to less than 9.4 kN within the following 60 seconds, an event is triggered.

rm_ruletype_jump_detection