Under Settings > Hardware Settings > General, basic hardware settings for HAL components such as cameras, barcode scanners, RFID readers, etc. are called up and changed.
Element |
Description |
---|---|
ShadowCopyDirectory |
Set file path for cloned or unzipped devices. Default value: OPCON_DATA_HOME |
JobsDirectory |
Set the file path for device jobs. |
IpcCallRetries |
Specify the number of retries when transferring HAL commands between Nexeed Rework Control and the devices. |
DevicesMergeMode |
Specify how the device manager hosts devices: 1: Only the hard-coded file path is used (without recourse to DevicesDirectory). 2: Accesses both the hard-coded file path and DevicesDirectory. 3: Only DevicesDirectory is used. Default value: 2 |
ConfigDirectory |
Specifies the directory in which the HAL component searches for the associated HAL configuration files. |
DevicesDirectory |
Specify a directory in which the device manager searches for additional devices (depending on DevicesMergeMode). If a file path is configured outside the root directory (for example, devices only), the device manager assumes that the configured directory is a subfolder of the config path. |
LogDirectory |
Specify the file path under which the HAL component stores trace data. |