The settings for a serial device are open and changed under Settings > Hardware settings > Serial.
Element |
Description |
---|---|
ScannerCommands |
Enter a freely selectable ASCII character string that is sent to the barcode scanner when the connection is established. |
Handshake. |
Select a handshake for the serial device: None: No control element is used for the handshake. XOnXOff: The XON/XOFF software control protocol is used. RequestToSend: Request-to-Send (RTS) hardware flow control is used. RequestToSendXOnXOff: Both the Request-to-Send (RTS) hardware flow control and the XON/XOFF software control protocol are used. Default value: None |
StopBits |
Select Stop Bits for data transfer (None, One, Two, OnePointFive) for the serial device. Default value: One/None The value selected in Nexeed Rework Control must match the value configured on the hardware side. |
DataBits |
Enter DataBits for the serial device (4, 5, 6, 7, 8). Default value: 8 |
Parity |
Select the data transmission parity (None, Odd, Even, Mark, Space) for the serial device. Default value: None |
Baud |
Enter the baud rate for the serial device (75, 110, 134, 150, 300, 600, 1200, 1800, 2400, 4800, 7200, 9600, 14400, 19200, 38400, 57600, 115200, 128000). Default value: 9600 |
COM |
Enter the COM port for the serial device. Default value: Attachment 1 Enter only a number, not a character string. |
ReReadDelayMs |
Enter the timeout for reading the data of the serial device (in milliseconds). Default value: 100 |
Active |
Specify the connection to the hardware. Default value: |
Shared |
Specify whether the device can also be used by other applications. Default value: |
Jobs |
Specify whether optional workflows are executed cyclically in HAL. Default value: |
MultipleInstancesAllowed |
Specify whether multiple instances of Nexeed Rework Control can be opened at the same time. Default value: |