The settings for the Balluff barcode reader are called up and changed under Settings > Hardware settings > Balluff.
Element |
Description |
---|---|
ResetUserPw |
Specify whether the user password can be reset. |
ResetUserName |
Specify whether the user name can be reset. |
ReconnectRetry |
Specifies the interval between two connection attempts (in ms). Default value: 5000 |
Commands: [0]: Active |
Specify whether to use a list of fixed commands. Default value: |
Commands: [0]: Name |
Enter the name for the list of permanently configured commands. Default value: Read Only possible if Commands: [0]: Active is activated. |
Commands: [0]: Command |
Enter the character string that is sent to the software. Default value: L0000001210 Only possible if Commands: [0]: Active is activated. |
SystemType |
Select the type of the connected Balluff barcode reader: None: No hardware type selected. To address the Balluff barcode reader with the standard protocol, select None. BIS_C: Driver for Balluff BIS-C hardware BIS_M: Driver for Balluff BIS-M hardware BIS_L: Driver for Balluff BIS-L hardware BIS_Z: Driver for BIS-Z hardware communication modules BIS_V: Driver for evaluation interface BIS-V BIS_U: Driver for Balluff BIS-U hardware Default value: BIS_V This value is only relevant when communicating via ASCII telegrams. The HAL component automatically determines whether communication is implemented via ASCII telegrams. |
UseBCC |
Specify whether the BCC checksum is appended to the telegram. Default value: |
Handshake. |
Select a handshake for the Balluff barcode reader: None: No control element is used for the handshake. XOnXOff: The XON/XOFF software control protocol is used. RequestToSend: Request-to-Send (RTS) hardware flow control is used. RequestToSendXOnXOff: Both the Request-to-Send (RTS) hardware flow control and the XON/XOFF software control protocol are used. Default value: None |
StopBits |
Select Stop Bits for data transfer (None, One, Two, OnePointFive) for the Balluff barcode reader. Default value: One/None The value selected in Nexeed Rework Control must match the value configured on the hardware side. |
DataBits |
Enter the data bits for the Balluff barcode reader (4, 5, 6, 7, 8). Default value: 8 |
Parity |
Select the data transmission parity (None, Odd, Even, Mark, Space) for the Balluff barcode reader. Default value: None |
Baud |
Enter the Baud rate for the Balluff barcode reader (9600, 14400, 19200, 38400, 57600, 115200, 128000). Default value: 9600 |
Port |
Enter the COM port for the serial connection. Default value: Attachment 1 Enter only a number, not a character string. |
NetworkAddress |
Enter the network address for the TCP version of the Balluff HAL component. Default value: Blank or network address (TCP) |
Abx |
Select Abx communication type. Default value: AUTO |
Active |
Specify the connection to the Balluff barcode reader. Default value: |
Shared |
Specify whether the Balluff barcode reader can also be used by other applications. Default value: |
Jobs |
Specify whether optional workflows are executed cyclically in HAL. Default value: |
MultipleInstancesAllowed |
Specify whether multiple instances of Nexeed Rework Control can be opened at the same time. Default value: |